Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Bone Loss Around Immediately Loaded Transitional Implants: Histologic and Microcomputed Tomographic Analysis—A Case Report
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 32 , Issue 6
December 2012

Pages 697 (e195–e203)


Bone Loss Around Immediately Loaded Transitional Implants: Histologic and Microcomputed Tomographic Analysis—A Case Report


Roberto Grassi, MD, DDS, PhD, MScD/Alberto Rebaudi, MD, DDS/Paolo Trisi, DDS/Ugo Covani, MD, DDS/Antonio Barone, DDS, PhD, MSc


PMID: 23057063
DOI: 10.11607/prd.00.1108

Immediate loading of dental implants can significantly decrease treatment time and thus increase patient acceptance. However, there is still a need to investigate whether an implant in which primary stability is achieved can be immediately loaded without the formation of connective fibrous tissue at the interface. Three transitional implants were placed in an edentulous mandible: two implants loaded immediately and one left unloaded. All transitional implants were retrieved after a period of 12 weeks to perform qualitative and quantitative analysis of the peri-implant tissue and bone-implant interface. Bone biopsy specimens containing the transitional implant were analyzed using microcomputed tomography (micro-CT). Subsequently, the same samples were analyzed using standard undecalcified histology. Micro-CT analysis showed that bone tissue was slightly detached from the surface of the loaded implant. Histology demonstrated the presence of a soft tissue layer inside the socket. Morphometric values of total bone volume, bone-implant contact, and bone connectivity were higher for the unloaded implant, which appeared to be covered by an almost continuous layer of bone. Micro-CT evaluation of some morphometric parameters and histologic results pertaining to small-diameter transitional implants showed that uncontrolled loading may produce untoward effects on peri-implant bone healing. (Int J Periodontics Restorative Dent 2012;32:e195–e203.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help